Category

Sabtu, 27 September 2014

Hydrotest Test Pressure

One and one-half times the maximum allowable working pressure or design pressure to be marked on the vessel when calculations are note made to determine the maximum allowable working pressure.

If the stress value of vessel material at the design temperature is less than at the test temperature, the hydrostatic test pressure should be increased proportionally.

Hydrostatic test shall be conducted after all facbrication has been completde. in this case, the test pressure shall be :

Vessel where the maximum allowable working pressure limited by the falngest, shall be tested at a pressure shown in the table above.

Hydrostatic test of Vessel of multi-chamber vessel : Code UG-99 (e).

Proof test to establish maximum allowable working pressure when the strength of any part of the vessel cannot be computed with satisfactory assurance of safety, predescribed in code UG-101.



Tidak ada komentar: